Tag Archives: drain leaks

Drain Troubles & Leaks

What could gurgling a rarely used wet bat sink when water drains in the kitchen at one end of the house or in a bath at the other end? Chances are that the wet bar is not vented or that its vent stack is blocked . You could check by looking for plumbing vent pipe protruding through the roof above the area. It will look like the ones above kitchen and bath.

Sluggish drainage is one symptom of this one problem . Sewer smell is another . When water drains in the kitchen or bath, its siphons water out of the wet bar’s drain trap , which produces a gurgling noise . Without the seal provided by water in the drain trap , sewer gas can rise up through th esink and into the house.

Big Backups
Even with proper venting, trap placement , and pipe sizing , drains still may be slow . This indicates a big blockage farther down the line. The best indicator that a blockage is in the waste line is sewage gurgling up through floor drains and basement fixtures. Solving this problem depends on your septic type.

If you have a septic system with a leachfield, your septic tank may need too be pumped out. This is a job for a professional , but it’s important to be around when the pumping concludes . Ask the pump operator if the tank was filled with enough greasy scum to cause the drain problems . If not the pipe’s in the leachfield itself may be the problem. Digging them up may be the solution.

If you’re tied into a municipal sewage system, check to see whether any work has been done on your branch line lately. If so , it could have caused problems with your drainage . If not, tree roots may have gotten into the pipes. Hire a professional to auger the line and pull out the tree roots , thereafter, flush copper sulfate root treatment through the line twice a year.

To find out whether the sink drainpipe or the flange in the sink is leaking, pour water leaks below , the problem is in the piping. If not, the problem is likely in the flange , clean off old caulk or plumbers putty ,install a fresh board of caulk , and retighten the flange . Leaks in the drainpipe generally occur in the trap . Some traps have a clean out nut that makes it easier to clean blockages.

To clear a stopped drain, you should start by using a plunger . For best results , block the over flow and second drain outlets; spread petroleum jelly on the rim of the plumbers helper, and use steady , forceful downward strokes to clear the clog . If this doe not work, you can try working a piece of wire , through the clean out plug and remove the blockage. However , snaking with a hand auger or power auger is much more effective . Disassemble the traps ; insert the auger and cleat out any blockages.

Draining & Filling System Prevention Leaks

Sediment gradually accumulates in any water based system reducing the system’s efficiency and damaging internal parts . Draining the boiler very season reduces the accumulation of sediment . Be aware that draining the system can take a long time, and the water often has a unpleasant odor. This does not indicate a problem . Drain the system during warm weather , and open the windows and run a fan to reduce andy odor.

Start by shutting of the boiler and allowing the hot system to cool. Attach a garden hose to the drain at the bottom of the the boiler, and place the valve on the highest radiator in the house .

When water stops draining , open a billed valve on a radiator closer to the boiler . When the flow stops , locate the valve or gauge on top of the boiler, and remove it with a wrench.

Maseru the stymie is cool before you add water. Close the drain valve on the boiler. Insert a funnel into the gauge fitting and rust inhibitor , available from heating supply dealers. Check the container for special instructions. Reinstall the valve or gauge in the top of the boiler , close all radiator bleed valves, and slowly reopen the water supply to the boiler .

When the water pressure gauge reads 5 psi, bleed the air from the radiators on the first floor, then do the same on the upper floors . Let the boiler reach 20 psi before you can turn the power on. Allow 12 hours for water to circulate fully, then bleed the radiators again.

Use a a garden hose to drain water from the boiler . Keep the drain end of the hose lower than the drain cock on the boiler .

If the valve or gauge on top of the boiler is attached to a separate fitting hold the fitting still with one wrench while removing the valve or gauge with another .

Using a funnel , add recommended rust inhibitor to the boiler through the valve or gauge fitting.

The boiler should reach a pressure of 20 psi berg you turn the power back on.

Replace Radiators Control Valves

A radiator control valve that won’t operate should be replaced . To replace the valve, you’ll first need to drain the system . Then use a pipe wrench to disconnect the nut on the outlet side of the valve , then disconnect the calve body from the supply pipe . Thread the tailpeace of the new calve into the radiator. Thread the valve body onto the supply pipe . Make sure the arrow on the valve body points in the direction of the water flow. Thread the connecting nut on the tailpiece onto the outlet side of the valve . When you recharge the system, open the bleed valve on the radiator until a trickle of the water runs out.

Drain Plumbing Water Damage Clean up Sewage Back up Problems

Drain problems causation and trouble shooting

What could cause gurgling in a rarely used wet-bar sink when water drains in the kitchen at one end of the house or in a bath at the other end? Chances are that the wet bar isn t vented or that its vent stack is blocked. You could check by looking for a plumbing vent pipe protruding through the roof above the area. It will look like the ones above kitchen and bath.

Sluggish drainage is one symptom of this problem. Sewer smell is another . When water drains in the kitchen or bath , it siphons water out of the wet bar s drain trap , which produces a gurgling noise. Without the seal provided by water in the drain trap , sewer gas can rise up through the sink and into the house .

If you don t use the wet-bar sink because of these problems , call a plumber to install an auto-vent. With this in place, the other drains won t siphon water out the trap. If you don t use it and don t really want it , have the plumber remove it and close the drain connection . In the meantime you can reduce the sewer gas smell by periodically pouring some water in the wet bar drain to keep the trap full.

Big Backups

Even with vapor venting, trap placement , and pipe sizing , drains still may be slow. This indicates a big blockage farther down the line. The best indicator that a blockage is in the waste line is sewage gurgling up through floor drains and basement fixtures. Solving this problem depends on your septic system type.

If you have a septic system with a leach field , your septic tank may need to be pumped out . This is a job for professional, but it s important to be around when the pumping concludes . Ask the pump operator if the tank was filled with enough greasy scum to cause the drain problems. If not , the pipes in the leach field itself may be the problem . Digging them up may be the only solution .

If your tied into a municipal sewage system , check to see whether any work has been done on your branch line lately . If so , it could have caused problems with your drainage , If not, tree roots may have gotten in the pipes . Hire a professional to auger the line and pull out the tree roots; thereafter , flush copper sulfate root treatment through the line twice year .

Do it yourself

There is snaking the kitchen line , clean out the pop up drain plugs hair clogged.. To access the trip waste linkage above the drain tub. If you cant get your toilet unclogged may have to remove the toilet snake it apply a new wax ring and reset it . Don t understand that process let a plumber handle it is just cheaper and safer, good luck.